Acoustic Test Cases

From Openmoko

(Difference between revisions)
Jump to: navigation, search
(New page: =Test Environment= 1.Normal temperature<br> 2.In the Anechoic Test Chamber<br> =Test Instruments= CMU200 Universal Radio Communication Tester<br> Conditioning Amplifier<br> UPL Audio Ana...)
 
 
(3 intermediate revisions by 2 users not shown)
Line 10: Line 10:
 
Artificial<br>
 
Artificial<br>
 
Mouth Simulator<br>
 
Mouth Simulator<br>
 +
 +
=Test Cases=
 +
==Test Case#1==
 +
Choose SEND item on the audio analyzer instrument<br>
 +
Test Item : Sending Frequency Response<br>
 +
The MS’s SLR is between 5 dB to 11 dB
 +
 +
==Test Case#2==
 +
Choose REC_MXMN item on the audio analyzer instrument<br>
 +
Test Item : Receiving Frequency Response<br>
 +
The MS’s RLR is between -13 dB to 18 dB
 +
 +
==Test Case#3==
 +
Choose STMR item on the audio analyzer instrument<br>
 +
Test Item : Sidetone Masking Rating<br>
 +
The MS’s STMR is between 13 dB to 23 dB
 +
 +
==Test Case#4==
 +
Choose ECHO_TCL→No TRNG item on the audio analyzer instrument<br>
 +
Test Item : Echo Loss<br>
 +
The MS’s TCLw is >46 dB
 +
 +
==Test Case#5==
 +
Choose DIST_SND→Rel 4/5 item on the audio analyzer instrument<br>
 +
Test Item : Sending Distortion<br>
 +
The audio analyzer instrument show PASS or FAIL
 +
 +
==Test Case#6==
 +
Choose DIST_REC item on the audio analyzer instrument<br>
 +
Test Item : Receiving Distortion<br>
 +
The audio analyzer instrument show PASS or FAIL
 +
 +
==Test Case#7==
 +
Choose IDLE_SND item on the audio analyzer instrument<br>
 +
Test Item : Idle Channel Noise Sending<br>
 +
The MS’s idle noise sending is <-64 dBm
 +
 +
==Test Case#8==
 +
Choose IDLE_REC→MAX item on the audio analyzer instrument<br>
 +
Test Item : Idle Channel Noise Receiving<br>
 +
The MS’s idle noise receiving is <-54 dBPa
 +
 +
[[Category:Test]]
 +
[[Category:Hardware Test]]

Latest revision as of 05:21, 11 June 2008

Contents

[edit] Test Environment

1.Normal temperature
2.In the Anechoic Test Chamber

[edit] Test Instruments

CMU200 Universal Radio Communication Tester
Conditioning Amplifier
UPL Audio Analyzer
Transformer
Artificial
Mouth Simulator

[edit] Test Cases

[edit] Test Case#1

Choose SEND item on the audio analyzer instrument
Test Item : Sending Frequency Response

The MS’s SLR is between 5 dB to 11 dB

[edit] Test Case#2

Choose REC_MXMN item on the audio analyzer instrument
Test Item : Receiving Frequency Response

The MS’s RLR is between -13 dB to 18 dB

[edit] Test Case#3

Choose STMR item on the audio analyzer instrument
Test Item : Sidetone Masking Rating

The MS’s STMR is between 13 dB to 23 dB

[edit] Test Case#4

Choose ECHO_TCL→No TRNG item on the audio analyzer instrument
Test Item : Echo Loss

The MS’s TCLw is >46 dB

[edit] Test Case#5

Choose DIST_SND→Rel 4/5 item on the audio analyzer instrument
Test Item : Sending Distortion

The audio analyzer instrument show PASS or FAIL

[edit] Test Case#6

Choose DIST_REC item on the audio analyzer instrument
Test Item : Receiving Distortion

The audio analyzer instrument show PASS or FAIL

[edit] Test Case#7

Choose IDLE_SND item on the audio analyzer instrument
Test Item : Idle Channel Noise Sending

The MS’s idle noise sending is <-64 dBm

[edit] Test Case#8

Choose IDLE_REC→MAX item on the audio analyzer instrument
Test Item : Idle Channel Noise Receiving

The MS’s idle noise receiving is <-54 dBPa
Personal tools

Test Environment

1.Normal temperature
2.In the Anechoic Test Chamber

Test Instruments

CMU200 Universal Radio Communication Tester
Conditioning Amplifier
UPL Audio Analyzer
Transformer
Artificial
Mouth Simulator